SFSE - Full Flat Element
SFSE Standard Features

- Iron-chrome aluminium resistance wire
- Heater Voltage: 230 Volts standard (other voltages available on request)
- Useful wavelength range: 2-10 microns
- Average Operating Life-Up to 20,000 hrs depending on conditions
UL approved (Click here for details)
- Recommended radiation distance from heater is 100 mm to 200 mm
Please click here for installation details
- Supplied with 100mm ceramic beaded power leads
| SFSE Technical Details | Wattage |
| 150 | 250 | 300 | 350 | 400 | 500 | 650 | 750 |
| Mean surface temperature |
262° C |
354° C |
400° C |
420° C |
464° C |
486° C |
589° C |
634° C |
| Max permissible operating temperature |
750°C |
750°C |
750°C |
750°C |
750°C |
750°C |
750°C |
750°C |
| Max power density kW/m² ( W/inch²) |
9 (5.8) |
15 (9.7) |
18 (11.6) |
21 (13.5) |
24 (15.5) |
30 (19.4) |
39 (25.2) |
45 (29) |
| Average weight |
231 g |
| Dimensions |
122 x 122 x 24 mm |
| Useful wavelength range |
2 to 10 µm |
SFSE drawing (pdf file)

Heat up / cool down graphs
|
Options Available Click choice for information
| Colours |
White |
|
| Yellow |
|
| Coral |
|
| Black |
|
| Others (on request) |
| Wire Terminations |
Ferrule (standard) |
|
| Ring termination |
| Contact us for alternatives |
| Thermocouples |
Type K
|
|
Type J
|
|
|
|