  Installation of Ceramic Elements  
     
Close-up shot for installation of ceramic element   The images show the installation arrangement for a ceramic infrared heating element. The element is pushed through the aluminised steel reflector. The stainless steel spring is then placed down over the power leads onto the element mounting pillar. The stainless steel clip is then slid into position as shown to retain the element in place. The clips and springs are provided with the elements.
     
Close-up shot for installation of ceramic element  

This system of retention allows the element to expand and contract within the reflector as it heats up and cools down.

Oval punching reflector slot dimensions: 42 mm x 15 mm

Click on either image for installation details.

     
Recommended Radiation Distance  
The recommended radiation distance of 100 mm to 200 mm
for industrial applications should be assumed.

Please contact Ceramicx Ireland for more detailed information about recommended radiation distances.

     
Installation Spacing  
The recommended minimum installation centre to centre spacing for the different types of elements is:
  • FTE - 250.0 mm, 62.5 mm
  • HTE -125.5 mm, 62.5 mm
  • QTE - 62.5 mm,  62.5 mm